Functional Characteristics
|
|
Provides laser ranging capability
|
|
Supports long-cycle laser designator, short-cycle laser designator, and emergency laser designator modes.
|
|
Includes built-in fixed frequency codes and supports online coding
|
|
Supports receiver detector lockout via command control; the receiver is locked by default at power-on.
|
|
Provides product temperature reporting.
|
|
Supports both internal trigger and external trigger operating modes.
|
|
Supports querying the laser emission count (cumulative count).
|
|
Provides energy adjustment capability for product maintenance.
|
|
Performance Parameters
|
|
Operating wavelength
|
1064 nm ± 3 nm
|
|
Energy (minimum)
|
≥ 120 mJ
|
|
Energy levels
|
50 mJ, 80 mJ, 120 mJ
|
|
Energy ranges per level
|
l 50–70 mJ
l 80–100 mJ
l ≥ 120 mJ
|
|
Energy stability
|
≤ ±10% per cycle (calculated after 2 s of laser designator)
|
|
Effective range (large target)
Laser ranging:
|
a) ≥ 30 km (conditions: visibility ≥ 45 km, target reflectivity 0.2, relative humidity ≤ 80%) b) ≥ 20 km (conditions: visibility ≥ 30 km, target reflectivity 0.2, relative humidity ≤ 80%) c) Minimum ranging distance: ≤ 300 m
|
|
Ranging accuracy
|
± 1 m
|
|
Repetition rate
|
Laser ranging: 1 Hz, 5 Hz
laser designator: 20 Hz
|
|
Valid measurement rate
|
≥ 98%
|
|
Pulse width
|
15 ns ± 5 ns
|
|
Beam divergence
|
≤ 0.15 mrad
|
|
Optical axis parallelism
|
Parallelism between mounting datum plane and optical axis ≤ 0.3 mrad
|
|
Operating modes
|
a) Laser ranging: continuous operation ≥ 10 min, rest 5 min b) Short-duration laser designator: Single laser designator duration ≥ 16 s, interval ≤ 9 s, 10 consecutive cycles; interval between major cycles ≤ 15 min c) Long-durationlaser designator: Single laser designator duration ≥ 60 s, interval ≤ 60 s, 5 consecutive cycles constitute one major cycle; interval between major cycles ≤ 30 min d) Emergency illumination (switching from ranging to laser designator): Single laser designator duration ≥ 16 s, interval ≤ 9 s, laser designator can be initiated at any time
|
|
Laser designator coding
|
a) 16 coding patterns b) Coding accuracy: ± 1 μs c) Coding range: 45,000 μs – 60,000 μs
|
|
Weight Requirements
|
|
Total unit weight
|
≤ 2 kg
|
|
Weight consistency
|
≤ 50 g
|
|
Structural Requirements
|
|
Overall dimensions
|
≤ 75 mm (W) × 90 mm (H) × 220 mm (L)
|
|
3D digital model requirements
|
The external model shall be complete and comprehensive, including details such as screws, cable routing, and mating connectors.
|
|
Load cable routing shall be included in the model design to avoid interference with the system.
|
|
Electrical Interface
|
|
DC input
|
18 V–32 V, typical supply 28 V
|
|
Average power consumption
|
≤ 120 W @ 28 V
|
|
Peak power consumption
|
≤ 200 W @ 28 V
|
|
Power-on inrush current
|
≤ 5 A @ 28 V
|
|
Digital ground, power ground, and mechanical housing shall be electrically isolated.
|
|
Environmental Adaptability Requirements
|
|
Operating Temperature
|
−40 °C to +60 °C
|
| Temperature entry — source label unresolved |
Withheld pending a corrected, controlled model specification. See the source-review note above. |
|
Vibration
|
|
Equipment vibration testing shall be conducted in accordance with MIL-STD-810G, Laboratory Environmental Test Methods for Military Equipment.
|
|
Vibration conditions
|
8.2 Hz – 86.4 Hz: 0.1 g²/Hz
156.4 Hz – 172.8 Hz: 0.025 g²/Hz
234.6 Hz – 259.2 Hz: 0.006 g²/Hz
Other frequency points within 15 Hz – 2000 Hz: acceleration spectral density of 0.004 g²/Hz
Vibration shall be applied along the X, Y, and Z axes, 15 minutes per axis.
|
|
Shock
|
|
Vertical axis
|
≥ 20 g
|
|
Lateral and longitudinal axes
|
≥ 15 g
|
|
Pulse duration
|
11 ms
|
|
3 axes, 2 directions per axis, 18 shocks in total
|
|
Shock testing shall be conducted in accordance with MIL-STD-810G, Laboratory Environmental Test Methods for Military Equipment.
|