The technical material below is retained for this model only. Do not transfer a range, pulse, interface, mechanical or safety value from another 1535 nm product.
Specifications
ER4000 is part of the 1535 nm erbium-glass pulsed laser family. Its current PDF lists pulse energy ≥4 mJ and optical pulse width 12 ns. Repetition-rate status is shown separately in the table. These are the source's distinct specifications; none establishes the distance or accuracy of a finished instrument.
| Parameter | Current PDF value |
| Model |
ER4000 |
| Laser Wavelength |
1535nm |
| Laser classification — source entry |
Class 1 (classification report and evaluated configuration require confirmation) |
| Pulse energy |
≥4 mJ |
| Laser Pulse width |
12 ns |
| Drive pulse width |
≤ 4 ms |
| Pulse repetition rate |
1~5Hz |
| Pulse stability |
10% |
| Raw Beam Diameter |
0.5 mm |
| Beam divergence angle |
≤ 4mrad |
| Beam Mode |
TEM00 |
| Operating temperature |
-40 ℃ ~ +65 ℃ |
| Storage temperature |
-55 ℃ ~+ 75℃ |
| Dimension (mm) |
60×25×13.5mm3 (Three linear dimensions in mm are listed; the source’s mm³ typography is not a calculated volume.) |
| Weight |
105 g |
| Voltage |
≤ 5 V |
| Electric current |
100 A |
| Shock |
1500 G, 0.5 ms |
| Vibration |
20~2000 Hz/20 G |
| Lifetime |
>1million shots |
Source-version clarification
Repetition rate: the current PDF table gives 1–5 Hz; its introduction gives 1–10 Hz. The table entry is displayed; the ordered repetition-rate rating is pending confirmation.
Reading this model's optical specifications
The recorded raw beam diameter is 0.5 mm and divergence is ≤ 4mrad. The current specification table does not state the divergence's full-angle/half-angle convention or the beam-width measurement method. Those definitions remain unspecified until a beam report confirms them. The beam-mode entry does not, by itself, supply a measured M² value.
Values above were checked against the current model PDF, including its inequality signs and stated measurement qualifiers. Source entries of “Class 1” require the corresponding classification report; shock, vibration and lifetime entries likewise need their stated test conditions. Missing tolerances and statistics are not reconstructed from another model or a paper.
Outline dimensions