Meet the LR1500E2
The LR1500E2 is a compact ranging module in the E2 mechanical format. It provides digital distance measurements for equipment that needs a ranging subsystem rather than a standalone handheld meter.
Its standard measurement range is 4–1500 m. The accuracy table uses a 500 m breakpoint, with a separate distance-dependent formula for longer measurements. Use the model-specific accuracy formula when setting your system requirements.
The UART-TTL interface supports host-controlled measurements. The manual includes test-software guidance, a six-pin interface definition, and a hexadecimal communication protocol. Use the E2 drawing for packaging and mounting.
01
1500 m range class
4–1500 m standard range with a model-specific long-distance accuracy formula.
02
Host-controlled ranging
2–10 Hz (adaptive); single-shot and continuous measurement modes.
03
Compact integration
25.7 × 13.3 × 24.6 mm nominal dimensions in the current mechanical drawing; detailed tolerances remain controlling.
04
UART-TTL interface
115200 bps communication and a 3.3–5 V supply range; use the model-specific pinout and command table.
TECHNICAL DATA
LR1500E2 Specifications
Read performance values with their target and test conditions. The linked user manual provides the complete mechanical, electrical, and communication details.
| Parameter | Value | Conditions / notes |
| Laser wavelength |
905 ± 5 nm |
— |
| Measurement range |
4–1500 m |
Standard range; actual reach depends on target and environment. |
| Ranging accuracy |
±1 m (6 m ≤ D < 500 m); ±(0.5 + 0.001D) m (500 m ≤ D ≤ 1500 m) |
Whiteboard target, 90% reflectivity: 2.3 × 2.3 m for the first distance interval; 2.3 × 4.6 m for the second. |
| Measurement update rate |
2–10 Hz (adaptive) |
Completed distance outputs; not the optical pulse-repetition rate. |
| Communication interface |
UART-TTL |
Custom configurations are specified separately. |
| Baud rate |
115200 bps |
— |
| Supply voltage |
3.3–5 V |
— |
| Operating temperature |
−20 °C to +55 °C |
— |
| Storage temperature |
−40 °C to +60 °C |
— |
| Mechanical drawing dimensions |
25.7 × 13.3 × 24.6 mm |
Drawing nominal values. Observe the individual tolerances in the model drawing; do not machine from the rounded summary alone. |
| Weight |
≤10 g |
— |
| Ingress protection |
IP67 |
Lens cavity only; not a blanket rating for the exposed board or the complete host product. |
| Laser safety class |
Class 1 |
As stated in the model manual; finished-equipment assessment is separate. |
| Laser beam divergence |
< 6 mrad (small laser spot) |
— |
| Optical material |
Resin aspheric lens |
— |
| Receiver aperture |
9.2 mm × 14.5 mm |
— |
| Startup time |
≤ 200 ms |
— |
| Inrush current |
≈ 350 mA |
Approximate value in the specification table. |
| Sleep power consumption |
< 1 mW |
— |
| Standby power consumption |
≈ 0.2 W |
Approximate value in the specification table. |
| Short-range power consumption |
≈ 0.4 W |
Approximate value in the specification table. |
| Operating power consumption |
≈ 1 W |
Approximate value in the specification table. |
- For civilian equipment only. The model manual prohibits military applications.
Operation and Data Output
Single-shot mode requests one reported distance. For a weak return, the manual describes repeated internal measurements before reporting stable distance data. Continuous mode produces repeated results at the documented adaptive update rate.
The standard measurement-rate specification is 2–10 Hz (adaptive). Higher-rate custom versions mentioned in the manual are separate configurations, not the default performance of a standard unit.
Electrical Interface
| Pin | Signal | Function |
| 1 |
GND |
Power ground |
| 2 |
VCC |
Power input |
| 3 |
I/O (Reserved) |
Reserved for expansion |
| 4 |
TXD |
Transmit data: module → host |
| 5 |
RXD |
Receive data: host → module |
| 6 |
SW-SHOT |
Function-enable input. The required control polarity must match the supplied configuration. |
Mechanical Dimensions
Use the drawing and its tolerances for installation. This drawing is reproduced directly from the current LR1500E2 user manual.